Self Test Report

This page documents an earlier firmware release. Read this page for the latest release

Report which contains the results of the selected self tests.

Table 1. Available fields in blickfeld.diagnostics.data.SelfTestReport
Field Type Default Unit

result_flag

Result.Flag

-

-

Aggregated result flag which is FLAG_SUCCESS if all tests passed without warnings

results

repeated Result

-

-

List of test results

Result

Result of test.

Table 2. Available fields in blickfeld.diagnostics.data.SelfTestReport.Result
Field Type Default Unit

test

config.SelfTest

-

-

Test case

identifier

string

-

-

Unique identifier of test case

flag

Flag

-

-

Flag which states test result

reason

optional string

-

-

Human-readable reason for test warning or failure. Is not set if test was successful.

duration

float

-

s

Duration of test run

Flag

Result flags which indicate if test was successful.

Table 3. Available values for blickfeld.diagnostics.data.SelfTestReport.Result.Flag enum
Name Value Description

FLAG_UNSPECIFIED

0

Unknown result.

FLAG_SUCCESS

1

The test was successful.

FLAG_WARNING

2

The test succeeded but it raised some warnings. Please report if this happens during production and the root-cause is unknown.

FLAG_FAILURE

3

The test failed. The tested module is most probably not functional.