Time Series
This page documents an earlier firmware release. Read this page for the latest release
Lifetime data series
This data is collected over the whole lifetime of the product. Currently the minimum, average, and maximum values are stored for 30 min intervals.
| Field | Type | Default | Unit |
|---|---|---|---|
binary |
- |
- |
|
Binary data |
|||
meta |
- |
- |
|
Meta information |
|||
Meta
Meta information about the lifetime series
| Field | Type | Default | Unit |
|---|---|---|---|
module |
string |
- |
- |
Module from which the data was collected |
|||
type |
- |
- |
|
Type of data |
|||
Binary
The fields of the series are encoded as binary arrays. Binary types instead of native Protobuf types are used to improve the performance.
| All byte arrays are encoded in Little Endian. |
| Field | Type | Default | Unit |
|---|---|---|---|
length |
uint32 |
- |
- |
Number of entries in arrays below. |
|||
timestamp |
bytes |
- |
- |
Timestamps of time series. Type: UInt64 |
|||
minimum |
bytes |
- |
- |
Aggregated minimum values. Type: Float32 |
|||
average |
bytes |
- |
- |
Aggregated average values. Type: Float32 |
|||
maximum |
bytes |
- |
- |
Aggregated average values. Type: Float32 |
|||