Connection

Requirements

  • For the data connection, a shielded Ethernet cable of Cat. 5E or higher is required.

  • For operating Qb2, Power over Ethernet (PoE) must be available. The corresponding equipment must support Type 1 powered devices (IEEE 802.3at) and be certified according to local safety standards and regulations.

  • For mounting the sensor, a mounting base is required. Contact Blickfeld for suitable mounting options.

Ethernet Interface

By default, Qb2 uses a 1000BASE-T Ethernet port for communication. This same port is used for powering the sensor via PoE technology.

When Qb2 is configured to communicate via the integrated WiFi interface, the Ethernet port is only used for powering the device.

Power over Ethernet

Qb2 is a Type 1 powered device (PD) according to the PoE standard IEEE 802.3at. It can be powered by any power supplying equipment (PSE) that conforms with the IEEE 802.3af and IEEE 802.3at standards.

Some PoE injectors available on the market, often designated as passive PoE, use different voltage levels than those defined by the IEEE 802.3af/at standards. Qb2 might not function properly if such injectors are used. Make sure to always use PoE equipment that complies with the aforementioned IEEE standards.

Connector specification

The wired network port of Qb2 is a IP67-rated M12 round connector (as per IEC 61076-2-109). The connector is supplied with a protective cap, which must be removed before the electrical installation. When no cable is connected to Qb2 and during storage, please put the cap back onto the connector.

Qb2 can only maintain its IP67 rating if either an Ethernet cable with IP67 rating or the protective cap is properly screwed onto the Ethernet port.

Qb2 M12 connector layout
Figure 1. Pinout of the M12 Ethernet receptacle on the sensor. For the pin assignment, see table below.
Table 1. M12 Ethernet receptacle pin assignment in conjunction with figure above.
Signals 1/10 Gbit/s Assignment M12 X-coded Color coding (TIA-568B)

BI_DA+

1

White/orange

BI_DA-

2

Orange

BI_DB+

3

White/green

BI_DB-

4

Green

BI_DC+

5

White/blue

BI_DC-

6

Blue

BI_DD+

7

White/brown

BI_DD-

8

Brown

Shield

Housing

Housing